Quantitative comparison and evaluation of two commercially available, two-dimensional electrophoresis image analysis software packages, Z3 and Melanie
- PMID: 12210223
- DOI: 10.1002/1522-2683(200207)23:14<2194::AID-ELPS2194>3.0.CO;2-#
Quantitative comparison and evaluation of two commercially available, two-dimensional electrophoresis image analysis software packages, Z3 and Melanie
Abstract
While a variety of software packages are available for analyzing two-dimensional electrophoresis (2-DE) gel images, no comparisons between these packages have been published, making it difficult for end users to determine which package would best meet their needs. The goal here was to develop a set of tests to quantitatively evaluate and then compare two software packages, Melanie 3.0 and Z3, in three of the fundamental steps involved in 2-DE image analysis: (i) spot detection, (ii) gel matching, and (iii) spot quantitation. To test spot detection capability, automatically detected protein spots were compared to manually counted, "real" protein spots. Spot matching efficiency was determined by comparing distorted (both geometrically and nongeometrically) gel images with undistorted original images, and quantitation tests were performed on artificial gels with spots of varying Gaussian volumes. In spot detection tests, Z3 performed better than Melanie 3.0 and required minimal user intervention to detect approximately 89% of the actual protein spots and relatively few extraneous spots. Results from gel matching tests depended on the type of image distortion used. For geometric distortions, Z3 performed better than Melanie 3.0, matching 99% of the spots, even for extreme distortions. For nongeometrical distortions, both Z3 and Melanie 3.0 required user intervention and performed comparably, matching 95% of the spots. In spot quantitation tests, both Z3 and Melanie 3.0 predicted spot volumes relatively well for spot ratios less than 1:6. For higher ratios, Melanie 3.0 did much better. In summary, results suggest Z3 requires less user intervention than Melanie 3.0, thus simplifying differential comparison of 2-DE gel images. Melanie 3.0, however, offers many more optional tools for image editing, spot detection, data reporting and statistical analysis than Z3. All image files used for these tests and updated information on the software are available on the internet (http://www.umbc.edu/proteome), allowing similar testing of other 2-DE image analysis software packages.
Similar articles
-
Comparison of three commercially available DIGE analysis software packages: minimal user intervention in gel-based proteomics.J Proteome Res. 2009 Feb;8(2):1077-84. doi: 10.1021/pr800588f. J Proteome Res. 2009. PMID: 19133722
-
Melanie II--a third-generation software package for analysis of two-dimensional electrophoresis images: I. Features and user interface.Electrophoresis. 1997 Dec;18(15):2724-34. doi: 10.1002/elps.1150181506. Electrophoresis. 1997. PMID: 9504804
-
New algorithmic approaches to protein spot detection and pattern matching in two-dimensional electrophoresis gel databases.Electrophoresis. 1999 Apr-May;20(4-5):755-65. doi: 10.1002/(SICI)1522-2683(19990101)20:4/5<755::AID-ELPS755>3.0.CO;2-6. Electrophoresis. 1999. PMID: 10344245
-
Numerical approaches for quantitative analysis of two-dimensional maps: a review of commercial software and home-made systems.Proteomics. 2005 Feb;5(3):654-66. doi: 10.1002/pmic.200401015. Proteomics. 2005. PMID: 15669000 Review.
-
Geometrical distortions in two-dimensional gels: applicable correction methods.J Chromatogr B Analyt Technol Biomed Life Sci. 2005 Feb 5;815(1-2):25-37. doi: 10.1016/j.jchromb.2004.07.037. J Chromatogr B Analyt Technol Biomed Life Sci. 2005. PMID: 15652796 Review.
Cited by
-
Feature detection techniques for preprocessing proteomic data.Int J Biomed Imaging. 2010;2010:896718. doi: 10.1155/2010/896718. Epub 2010 May 5. Int J Biomed Imaging. 2010. PMID: 20467457 Free PMC article.
-
The path to enlightenment: making sense of genomic and proteomic information.Genomics Proteomics Bioinformatics. 2004 May;2(2):123-31. doi: 10.1016/s1672-0229(04)02018-2. Genomics Proteomics Bioinformatics. 2004. PMID: 15629052 Free PMC article.
-
Spot quantification in two dimensional gel electrophoresis image analysis: comparison of different approaches and presentation of a novel compound fitting algorithm.BMC Bioinformatics. 2014 Jun 11;15:181. doi: 10.1186/1471-2105-15-181. BMC Bioinformatics. 2014. PMID: 24915860 Free PMC article.
-
Ocular proteomics with emphasis on two-dimensional gel electrophoresis and mass spectrometry.Biol Proced Online. 2009 Dec 24;12(1):56-88. doi: 10.1007/s12575-009-9019-7. Biol Proced Online. 2009. PMID: 21406065 Free PMC article.
-
Two-Dimensional Gel Electrophoresis Image Analysis.Methods Mol Biol. 2021;2361:3-13. doi: 10.1007/978-1-0716-1641-3_1. Methods Mol Biol. 2021. PMID: 34236652
Publication types
MeSH terms