Next line returns 200 as status https://github.com/Kong/kong/blob/c817fada7a514d84f6e0aab7461605c71bf3a841/kong/plugins/cors/handler.lua#L13
Internet says it should return 204:
- https://developer.mozilla.org/en-US/docs/Glossary/Preflight_request
- https://docs.microsoft.com/en-us/aspnet/core/security/cors?view=aspnetcore-3.1#preflight-requests
Internet changed its mind since 2018 https://
-
Updated
Feb 3, 2021 - C
-
Updated
Mar 5, 2021 - C
-
Updated
Mar 5, 2021 - C
-
Updated
Mar 4, 2021 - JavaScript
The uncompensated temperature of the BMP180 is incorrectly converted to a 16-bit signed value, instead of a 32-bit signed value (long). Since the data is 16-bits wide and can therefore not be negative, the easy fix would be to do the following:
sip.js(1128): uncompensated = uint16(data[0], data[1]);
Please see page 15 of the manual of the BMP180 chip:
https://ae-bst.resource.bosch.com/media
Description
The docs confused me a bit today: the Renderers page lists the gpg renderer as a text renderer. At the same time the salt.rendereres.gpg page uses it as a data renderer (last in the pipeline). This confused me for
-
Updated
Mar 5, 2021 - C
-
Updated
Mar 5, 2021 - Java
-
Updated
Mar 5, 2021 - Erlang
-
Updated
Mar 2, 2021 - Go
A common protocol structure is to have a header containing a length
field, followed by data of length
bytes, followed by additional protocol fields such as a CRC. If the length field is variable, the position of subsequent URH-specified protocol fields defined by fixed position will not be in the correct location.
I do not know the best way to address this, but quick and easy way to support
-
Updated
Aug 26, 2020 - C#
-
Updated
Mar 4, 2021 - C
-
Updated
Mar 5, 2021 - C
-
Updated
Mar 5, 2021 - C++
-
Updated
Mar 2, 2021 - C++
-
Updated
Mar 4, 2021 - Python
Starting point: a default, single-node microk8s installation (snap install microk8s --classic --channel=1.19
) with several deployments installed through GitLab integration, including database pods with persistent volumes (storage
addon).
Running microk8s disable ha-cluster
deletes all deployments, all services, all pods, and all persistent volumes without any warning. Everything is gone
Summary of Problem
Not able to open port with stopbits as 1.5
I am currently building a desktop client using electron, where the COM port receives data correctly for values: baudRate: 2400, dataBits: 7, stopBits: 1.5, parity: 'none'
I found from the node-serialport documentation, stopBits Must be one of these: 1 or 2. But, should 1.5 be supported as well? especially for old & slow
Hi, the SkyWalking has released Lua Nginx 0.4.0, we should upgrade its version.
[1] https://skywalking.apache.org/events/release-apache-skywalking-lua-nginx-0.4.0/
[2] https://github.com/apache/apisix/blob/master/rockspec/apisix-master-0.rockspec#L57
Is your enhancement proposal related to a problem? Please describe.
Refer to: zephyrproject-rtos/zephyr#28932
Describe the solution you'd like
Refer to: zephyrproject-rtos/zephyr#28932 (comment)
Describe alternatives you've considered
NA
Additional context
NA
-
Updated
Oct 2, 2020 - JavaScript
-
Updated
Mar 5, 2021 - C
-
Updated
Mar 5, 2021 - Java
What would you like to be added/modified:
To improve project stability, we need more tests to cover corner cases.
And the code coverage is around 50% currently, we need to add more tests to improve it.
To improve case coverage, we may need a list of cases to track the work.
For code coverage, simply check bef
Improve this page
Add a description, image, and links to the iot topic page so that developers can more easily learn about it.
Add this topic to your repo
To associate your repository with the iot topic, visit your repo's landing page and select "manage topics."
Feature idea summary
Cgroups plugin supports only proportional and max Block IO policies. We should support BFQ scheduler as well. Disk stats for the scheduler are in
blkio.bfq.io_service_bytes
andblkio.bfq.io_serviced
files.